[:SENSe]:EDETector:TRACe{1:4}[:FUNCtion] <char>

(Read-Write) Set and query the display state of a EMI band detector trace.

See also, MEAS, CISP:BAND, FREQ:AXIS:LOG, BAND:APD:RES, BAND:EMI:RES, BAND:EMI:AUTO, BAND:APD:AUTO, SWE:EMI:DWEL, SWE:APD:DWEL, TRAC<v>:APD:INPUT.

Relevant Modes

EMI (Opt 361)

Parameters

 

{1:4} == <n>

Trace number. If unspecified, value is set to 1.

For EMI mode Choose from 1 to 4.

<char>

These arguments (PEAK | QPD | EAV) cannot be reassigned to another trace, but the trace can be enabled or disabled.

PEAK - Peak positive detection.

QPD - Quasi-peak detection.

EAVerage - EMI average detection.

NOTE: Trace 4 can be assigned to any of the three choices above.

 

Examples

EDET:TRAC1 1

Query Syntax

[:SENSe]:EDETector:TRACe<v>[:FUNCtion]?

Default

1 - PEAK

2 - QPD

3 - EAV

4 - PEAK


Last Modified

 

31-Aug-2023

New command